What are the benefits of using precision air conditioning in the server room?
  • Home
  • blog
  • What are the benefits of using precision air conditioning in the server room?

What are the benefits of using precision air conditioning in the server room?

July 28, 2022

Air conditioners can regulate temperature, humidity and air cleanliness, so air conditioners are used in many industries, but for some specific functions of the room can not do, need to install precision air conditioning, such as machine rooms, laboratories, instrument rooms, museum storage rooms and other places.

Precision air conditioners are also known as constant temperature and humidity air conditioners, which can accurately control the humidity and temperature of the environment. Precision air conditioners are characterized by large air supply volume, small enthalpy difference, high sensible heat ratio and high air purification rate. The humidity change rate is less than 10% RH/h (when the humidity is set at 40%-60%) and the humidity can be accurate to ±3%, and the temperature change rate is less than 5/h (when the temperature is set at 15-30) and the temperature can be accurate to ±0.5. The design life of precision air conditioning can reach 10 years, continuous operation time up to 86,400 hours, the average failure-free rate reached 25,000 hours, the better maintenance of precision air conditioning can run about 15 years.

The benefits of using precision air conditioning in the server room are mainly as follows.

1. High temperature constancy.

The high-speed operation of the equipment in the server room will bring a large amount of heat, in order to maintain the normal operation of the equipment, it is necessary to control the equipment in the state of constant temperature environment. If the temperature of the room can not be constant, it is easy to cause the electronic components of the equipment to reduce the life, when there is a high ambient temperature brought about by the local overheating of the equipment, will cause the equipment to burn or downtime.

2. High humidity constancy. The humidity of the environment in the server room affects the service life of the equipment and brings safety hazards. If the humidity of the room is too high, the low-temperature environment will appear too much condensation, dripping on the equipment to cause burn or even fire; if the humidity of the room is too low, after the air becomes dry, it is easy to generate static electricity, which will also cause certain dangers.

3. High air cleanliness.

There are many precision instruments and electrical components in the server room, fine dust can easily lead to short circuits. Precision air conditioning has a better ability to filter air impurities, the air sent into the room are clean, reducing dust scattered on the equipment components, triggering equipment short-circuit, overheating, and the phenomenon of data errors.

4. Air supply volume.

Precision air conditioning equipment are relatively large, through a special air duct for air treatment after feeding, in the face of heat dissipation is relatively large electronic equipment without sufficient air volume is difficult to achieve uniform cooling of equipment, and precision air conditioning has more than ordinary air conditioning more than 1 times the volume of large air supply, can quickly pump away the heat in the room, to achieve the purpose of rapid cooling equipment.

In short, ordinary air conditioning is facing the living environment of personnel, for the server room, heat dissipation is relatively large, the higher demand for air conditioning heat dissipation; cooling the continuous working time is relatively long, almost all 24 hours in a row; the temperature should be controlled between 22 -24 ; the humidity should be controlled between 50% ± 5%; the cleanliness should be controlled in ASHRAE 20% +, the more accurate the control is the better The more precise the control is, the better the control is; to cope with the outdoor ambient temperature is also stronger, can withstand -35 to -42 environment, for the above conditions precision air conditioning can do, ordinary air conditioning can not meet. Precision air conditioning to ensure constant temperature, constant humidity, constant cleanliness and long life of the server room.

 

 