Data center usually refers to the centralized processing, storage, transmission, exchange and management of information in a physical space. The key physical infrastructure of data center to guarantee critical running contains power supply system, refrigeration system, cabinet system, fire protection system and monitoring system.

  • Coolnet I-Module Modular Data Center Solution adopts a modular design and integrates data center infrastructure subsystems such as cabinet systems, channel systems, power supply and distribution systems, air conditioning systems, and monitoring systems to provide customers with rapid deployment, high efficiency, energy saving, a new type of data center with compact space and flexible expansion can effectively meet customers' requirements for efficient, reliable, fast, flexible, and intelligent management of data centers in the cloud era. Power 3N-380V-50HZ Operating Voltage 380v/220v Cooling In-row Precision Air Conditioning UPS Power Supply 380VAC/400VAC/415VAC(3Phase 5Wire),50/60Hz Certification CE,ISO Monitoring System Power supply, battery, power distribution, air conditioning,etc.

    Tags : Modular Data Center In Row Air Conditioning Closed Cold Aisle Integrative Modular Data Center

    Read More
  • COOLNET CN-UT series three-input three-output UPS is a sine wave on-line high-performance uninterruptible power supply. High-performance sine wave online UPS designed with small intelligent equipment (such as measuring devices, industrial automation equipment, etc.), precision instruments, etc. In particular, adapting the generator as an AC source input can effectively isolate the bad power generated by the generator, avoid grid pollution, and provide a pure, safe and stable power supply for the load. Capacity Connection Mode 10KVA -30KVA Three phase+Four wire Input Voltage Output Voltage 380/400/415VAC 200/208/220/230/240VAC Frequency Battery Cells 40-70Hz 16-20 optional

    Tags : Single Phase UPS Uninterrupted Power Supply Data Center Uninterrupted Power Supply UPS Tower UPS Uninterrupted Power Supply 10KVA UPS 30KVA UPS Three Phase Tower UPS

    Read More
  • Coolnet I-Container series containerized outdoor data center infrastructure solution that integrates functions such as power supply and distribution, temperature control, cabinets, management, fire protection, lightning protection and grounding, and is used to carry IT equipment and provide stable, reliable, and energy-saving power ring system. Applicable to multiple industries and scenarios, it has minimalist, green, intelligent and safe features. The internal components of the container data center include: cabinets, power distribution cabinets, UPS, batteries, air conditioners, fire protection, security and monitoring systems. Container Size 20'/40' HQ Rack Quantity 4-10 pcs Single Rack Capacity 3-10KW Rated Power 380/400/415 VAC Cooloing System In-row precision air conditionings Power Supply 25kva*2/25kva*4 N+1 modular UPS

    Tags : Prefabricated Container Data Center Container Data Center Mobile Data Center

    Read More
  • Coolnet Hot&amp Cold Aisle Containment is an integrated Modular Data Center Solution which can flexibly adopt the layout of double-row cabinets + cold/hot aisle or single-row cabinets + cold/hot aisle according to user site conditions. Under the two structural layouts, all subsystems such as cabinets, channels, power supply and distribution, refrigeration, security, environmental monitoring and management, and wiring can be integrated according to user needs, providing customers with new data of rapid deployment, high efficiency and energy saving, compact space, and flexible expansion central solution. Power 3N-380V-50HZ Operating Voltage 380v/220v Cooling In-row Precision Air Conditioning UPS Power Supply 380VAC/400VAC/415VAC(3Phase 5Wire),50/60Hz Certification CE,ISO Monitoring System Power supply, battery, power distribution, air conditioning,etc.

    Tags : Hot And Cold Aisle Containment Prefabricated Container Data Center Modular Data Center Integrative Modular Data Center

    Read More
  • Coolnet Bitcoin Mining Data Center (CBMDC) is a MOBILE mining farm which adopts with standard 20ft or 40ft container size for construction. It has excellent facility for migration and can work anywhere after connecting electricity and networks. Stable quality ensures the smooth running which guarantee sustainable good yield. The low power consumption, easy mobility, and high working stability makes it as an iconic design in the cryptocurrency mining industry. Mobile Data Center Size AntMiner units 20Ft Container Size 150 units/20Ft Container Size 40Ft Container Size 300 units/40Ft Container Size Capacity Cooling Type 12kw-75kw Air Cooling Transportability Configuration Support Customized

    Tags : Hot And Cold Aisle Containment Prefabricated Container Data Center Outdoor 20ft Container Data Center Container Data Center

    Read More
  • CN-UT series All intelligent high frequency pure online UPS, which are generally used on places required high quality electricity, such as hospital equipment, corporations, IT loading equipment, industrial computer terminal. As UPS inverter circuit always in a working state, the stored energy of UPS can be inverted and output alternating current without switching. Capacity Connection Mode 10KVA -30KVA Three phase+Four wire Input Voltage Output Voltage 380/400/415VAC 200/208/220/230/240VAC Frequency Battery Cells 40-70Hz 16-20 optional

    Tags : Single Phase UPS Uninterrupted Power Supply Data Center Uninterrupted Power Supply UPS Tower UPS Uninterrupted Power Supply 10KVA UPS 30KVA UPS Three Phase Tower UPS

    Read More
  • STS static transfer switch (Static Transfer Switch) is an automatic switching system of two power sources. Under normal working conditions, when the main power supply is within the normal voltage range, the load is always connected to the main power supply. The STS static transfer switch adopts the switching method of break before make. Uninterrupted switching between different input power sources can be achieved. MSTS is called Multiple Spot Temperature Sensor Static Transfer Switch and it is a kind of rapid load transfer switch, with the minimum transfer time of 3.2 ms. It is suitable for use in the in-phase and out-of-phase conditions. Besides of load transfer mentioned above, MSTS connection with multiple sets is also available to form output of n+1=1 type, which can further increase power supply safety. Standard Capacity 3-6KW Rated Current 16-30A Output Interface IEC C13 / C19 Input Voltage 200-240VAC Output voltage 200-240VAC Output Efficiency More than 98%

    Tags : STS MSTS Static Transfer Switch

    Read More
  • COOLNET DCIM full name is Data Center Infrastructure Management. It is used in data room and generally has the functions for management of asset, capacity, operation and maintenance, energy consumption, and dynamic environment. It is the convergence of IT and building facilities functions within an organization. The goal of a DCIM initiative is to provide administrators with a holistic view of a data center's performance so that energy, equipment and floor space are used as efficiently as possible. Asset Management Capacity Management Precision Air Conditioners, Servers, Storage Equipment etc. Basic settings of air conditioning system, power supply etc. Operation and Maintenance Management Energy Consumption Management Fault handling, daily maintenance and inspection Energy consumption analysis, PUE situation analysis

    Tags : DCIM Data Center Infrastructure Management Data Center DCIM

    Read More
  • Embedded power supply system integrates multiple function, including DC current limiting, peak surge absorption, comprehensive automatic protection, battery intelligent management, unattended, intelligent remote monitoring and other functions. The components of the system are divided into two parts: power supply and battery, the cabinet structure is divided into one-piece and split type,indoor or outdoor design. The power supply section includes: AC distribution unit, rectifier module, monitoring unit and control circuit.Each functional unit is designed in standardized sizes, with power supply heights ranging from 1U to 9U.It meets the wide range of DC outputs from 30A to 400A and is a DC power supply system with a wide range of application scenarios. Rack height Installation method 1U-9U Embedded installation input voltage Output voltage range 220Vac,50Hz 42-58Vdc

    Tags : 48V DC Power Supply Power Supply System DC Power Supply

    Read More
  • COOLNET lead-acid battery (VRLA) is a battery whose electrodes are mainly made of lead and its oxides, and the electrolyte is a sulfuric acid solution. The nominal voltage of a single-cell lead-acid battery is 2.0V, which can be discharged to 1.5V and charged to 2.4V; In applications, 6 single-cell lead-acid batteries are often connected in series to form a nominal 12V lead-acid battery , as well as 24V, 36V, 48V, etc. Capacity Efficiency 100-3000A Above 99.99% Nominal Voltage Openning Pressure 2V 10-20Kpa Rated Life Warranty Up to 15 years 3 years

    Tags : Portable Backup UPS With Charge By Solar 12V VRLA Battery 2V VRLA Battery

    Read More
  • COOLNET Lithium Battery is an excellent energy source for 48V applications. It is especially designed for telecom sites due to its extraordinary features: better charging and discharging performance, longer lifespan, smaller size, and theft-proof design. The energy storage system provides a perfect replacement for Lead Acid Battery. Due to the advantages of ultra-long life, safe use, large capacity, and green environmental protection, the transfer of lithium iron phosphate batteries to the field of energy storage will extend the value chain, which is conducive to promoting new business models and constructing a new industrial chain. Cathode Material Rated Voltage LiFePO4 48VDC Max Charging/Discharging Current Max Discharging Power 100A/100A@35℃ 4800W Cycle Life Charging Current Limit 3000 cycles 10A

    Tags : 48V Lithium Battery

    Read More